Top of the page

Conductivity cell, WTW TetraCon 325-1, 4 graphite, K=0,475 cm-1, NTC, 8-pole plug 1,5 m

Item No. 5177010
Conductivity cell probes TetraCon® 325 standard conductivity cell probe: 4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2S/cm. LR 325/01 ultra-pure water conductivity cell probe: With integral temperature sensor and flowthrough vessel D 01/T for mea
In stock - Log in for price

Description

Conductivity cell probes

TetraCon® 325 standard conductivity cell probe:
4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2S/cm.

LR 325/01 ultra-pure water conductivity cell probe:
With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 mS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range: 0.001µS/cm to 200µS/cm.

TetraCon® DU/T conductivity flowthrough cell:
4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1mS/cm to 1000mS/cm.
Type TetraCon® 325
Electrode Graphite
Shaft diameter Epoxy resin
Length 120 mm
Cell constant K =0,475

Pack: 1 each

Specifications

Producent
WTW
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115610 Ledningsevne celler
Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022

Conductivity cell, WTW TetraCon 325-1, 4 graphite, K=0,475 cm-1, NTC, 8-pole plug 1,5 m

Item No. 5177010
Conductivity cell probes TetraCon® 325 standard conductivity cell probe: 4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2S/cm. LR 325/01 ultra-pure water conductivity cell probe: With integral temperature sensor and flowthrough vessel D 01/T for mea
In stock - Log in for price

Description

Conductivity cell probes

TetraCon® 325 standard conductivity cell probe:
4-pole cell with integral temperature sensor. Cable length 1.5 metres. Measuring range: 1µS/cm to 2S/cm.

LR 325/01 ultra-pure water conductivity cell probe:
With integral temperature sensor and flowthrough vessel D 01/T for measuring very low conductivity ranges (<1 mS/cm) e.g. boiler feed water or deionised water. Cable length 1.5 metres. Min. / max. insertion depth 35 / 110mm and flowthrough, measuring range: 0.001µS/cm to 200µS/cm.

TetraCon® DU/T conductivity flowthrough cell:
4-pole conductivity cell with integral temperature sensor for standard applications. Connection via 10mm diameter tubing nozzles (the adapter cable KKDU with 1 metre cable is required for connection). Filling volume 7ml. Measuring range: 1mS/cm to 1000mS/cm.
Type TetraCon® 325
Electrode Graphite
Shaft diameter Epoxy resin
Length 120 mm
Cell constant K =0,475

Pack: 1 each

Specifications

Producent
WTW
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115610 Ledningsevne celler
Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022