pH electrode, Mettler-Toledo LE410, glass, NTC, BNC/RCA 1 m
Description
The pH electrode LE410 from Mettler-Toledo has a glass shaft, temperature sensor, and a fixed cable. The sensor is developed for general use in laboratories, with focus on quick results in aqueous solutions. With refillable liquid electrolyte. Shipped with fixed cable.
The LightEdition (LE) sensors are tailor-made for high price/performance ratio. The LE range includes sensors for all common applications and focuses on low maintenance and easy handling.
Specifications
- pH range: 0 - 14
- Temperature range: 0 - 80 °C
- Shaft material: Glass
- Membrane glass type: HA - High alkali glass with low alkali errors for high pH values and high temperatures
- Membrane resistance (25 °C): <600 MΩ
- Temperature sensor: NTC 30 kΩ
- Reference system: Ag/AgCl
- Reference electrolyte: 3 mol/L KCl Ag saturated
- Shaft length: 120 mm
- Shaft diameter: 12 mm
- Connection: BNC / RCA (cinch)
- Cable length: 1 m
Specifications
- Producent
- Mettler-Toledo
- Type
- Elektrolyt refill
- Temperature [°C]
- 0 - 80
- Diameter [mm]
- 12
- Length [mm]
- 120
- Materials
- Glas
- Model
- Mettler LE
- Max. pH
- 14
- Min. pH
- 0
- Qty per Salesunit
- 1 each
- Sales Unit of Measure
- EA
- UNSPSC
- 41115604 pH-elektroder
- Any questions, please contact
- Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022
pH electrode, Mettler-Toledo LE410, glass, NTC, BNC/RCA 1 m
Description
The pH electrode LE410 from Mettler-Toledo has a glass shaft, temperature sensor, and a fixed cable. The sensor is developed for general use in laboratories, with focus on quick results in aqueous solutions. With refillable liquid electrolyte. Shipped with fixed cable.
The LightEdition (LE) sensors are tailor-made for high price/performance ratio. The LE range includes sensors for all common applications and focuses on low maintenance and easy handling.
Specifications
- pH range: 0 - 14
- Temperature range: 0 - 80 °C
- Shaft material: Glass
- Membrane glass type: HA - High alkali glass with low alkali errors for high pH values and high temperatures
- Membrane resistance (25 °C): <600 MΩ
- Temperature sensor: NTC 30 kΩ
- Reference system: Ag/AgCl
- Reference electrolyte: 3 mol/L KCl Ag saturated
- Shaft length: 120 mm
- Shaft diameter: 12 mm
- Connection: BNC / RCA (cinch)
- Cable length: 1 m
Specifications
- Producent
- Mettler-Toledo
- Type
- Elektrolyt refill
- Temperature [°C]
- 0 - 80
- Diameter [mm]
- 12
- Length [mm]
- 120
- Materials
- Glas
- Model
- Mettler LE
- Max. pH
- 14
- Min. pH
- 0
- Qty per Salesunit
- 1 each
- Sales Unit of Measure
- EA
- UNSPSC
- 41115604 pH-elektroder
- Any questions, please contact
- Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022