Top of the page

pH electrode, Mettler-Toledo InLab Viscous Pro-ISM, glass, NTC, MultiPin wo. cable

Item No. 9041551
The pH electrode InLab® Viscous Pro-ISM from Mettler-Toledo has been especially developed for viscous and highly glutinous samples. The SteadyForce™ reference system is under pressure (3 bar) and guarantees the discharge of electrolytes, even with the most glutinous and fatty of samples, e.g. cosmet

Description

The pH electrode InLab® Viscous Pro-ISM from Mettler-Toledo has been especially developed for viscous and highly glutinous samples. The SteadyForce™ reference system is under pressure (3 bar) and guarantees the discharge of electrolytes, even with the most glutinous and fatty of samples, e.g. cosmetics, paints or resins. The form has been chosen so that as little of the sample as possible adheres to the shaft and to facilitate cleaning. The result is a problem solver for most difficult sample types, the highly viscous materials. Shipped without cable.

Measurements in solid or viscous samples is challenging and requires electrodes which are robust, ensure correct flow of electrolyte, and that are easy to clean. Sensors with these traits are often used for applications in the industries of food, beverage, and cosmetics.

ISM - Intelligent Sensor Management: When the electrode is connected to an ISM-compatible instrument, it offers the option for safe and automatic documentation. The calibration data and sensor ID for the ISM sensor is automatocally transferred to the instrument, and the sensor saves the factory-issued calibration, as well as the latest 5 calibrations. In addition, the maximum temperature that the sensor has been exposed to, will be logged.

Specifications

  • pH range: 0 - 14
  • Temperature range: 0 - 130 °C
  • Shaft material: Glass
  • Membrane glass type: HA - High alkali glass with low alkali errors for high pH values and high temperatures
  • Membrane resistance (25 °C): <600 MOhm
  • Temperature sensor: NTC 30 kOhm
  • Reference system: SteadyForceâ„¢
  • Reference electrolyte: FRISCOLYT-C®
  • Shaft length: 160 mm (120 / 40)
  • Shaft diameter: 12 / 6 mm
  • Cable connection: MultiPinâ„¢ plug
Pack: 1 each

Specifications

Producent
Mettler-Toledo
Type
Gel/polymer
Temperature [°C]
0 - 130
Diameter [mm]
6
Length [mm]
40
Materials
Glas
Model
InLab Viscous
Max. pH
14
Min. pH
0
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115604 pH-elektroder
Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022

pH electrode, Mettler-Toledo InLab Viscous Pro-ISM, glass, NTC, MultiPin wo. cable

Item No. 9041551
The pH electrode InLab® Viscous Pro-ISM from Mettler-Toledo has been especially developed for viscous and highly glutinous samples. The SteadyForce™ reference system is under pressure (3 bar) and guarantees the discharge of electrolytes, even with the most glutinous and fatty of samples, e.g. cosmet

Description

The pH electrode InLab® Viscous Pro-ISM from Mettler-Toledo has been especially developed for viscous and highly glutinous samples. The SteadyForce™ reference system is under pressure (3 bar) and guarantees the discharge of electrolytes, even with the most glutinous and fatty of samples, e.g. cosmetics, paints or resins. The form has been chosen so that as little of the sample as possible adheres to the shaft and to facilitate cleaning. The result is a problem solver for most difficult sample types, the highly viscous materials. Shipped without cable.

Measurements in solid or viscous samples is challenging and requires electrodes which are robust, ensure correct flow of electrolyte, and that are easy to clean. Sensors with these traits are often used for applications in the industries of food, beverage, and cosmetics.

ISM - Intelligent Sensor Management: When the electrode is connected to an ISM-compatible instrument, it offers the option for safe and automatic documentation. The calibration data and sensor ID for the ISM sensor is automatocally transferred to the instrument, and the sensor saves the factory-issued calibration, as well as the latest 5 calibrations. In addition, the maximum temperature that the sensor has been exposed to, will be logged.

Specifications

  • pH range: 0 - 14
  • Temperature range: 0 - 130 °C
  • Shaft material: Glass
  • Membrane glass type: HA - High alkali glass with low alkali errors for high pH values and high temperatures
  • Membrane resistance (25 °C): <600 MOhm
  • Temperature sensor: NTC 30 kOhm
  • Reference system: SteadyForceâ„¢
  • Reference electrolyte: FRISCOLYT-C®
  • Shaft length: 160 mm (120 / 40)
  • Shaft diameter: 12 / 6 mm
  • Cable connection: MultiPinâ„¢ plug
Pack: 1 each

Specifications

Producent
Mettler-Toledo
Type
Gel/polymer
Temperature [°C]
0 - 130
Diameter [mm]
6
Length [mm]
40
Materials
Glas
Model
InLab Viscous
Max. pH
14
Min. pH
0
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115604 pH-elektroder