Turbidity meter, WTW Turb 430 IR, LED, w. accessories
Description
Turbidity meter from WTW - Turb® 430 IR
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.
The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-100 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.
Scope of delivery: Turbidity meter with calibration set 0.02-10.0-100 NTU
Specifications
Type Turb® 430 IR with infra red LED
Measuring range: NTU 0 to 1100, FNU 0 to 1100
Resolution: 0.01 in the range 0.00 to 9.99, 0.1 in the range 10 to 99.90, 1 in the range 100 to 1100
Accuracy: ± 0.01 NTU or ± 2 % of measured value
Reproducibility: 0.01 NTU or < 0.5% vof measured value
Cell size: 28 x 60 mm, 20 ml sample volume
Power supply: 4 x AA batteries for approx. 3000 measurements
Specifications
- Producent
- WTW
- Qty per Salesunit
- 1 each
- Sales Unit of Measure
- EA
- UNSPSC
- 47101516 Turbidimetre
- Any questions, please contact
- Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022
Turbidity meter, WTW Turb 430 IR, LED, w. accessories
Description
Turbidity meter from WTW - Turb® 430 IR
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.
The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-100 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata. The quality assurance of the measured results is supported by calibration interval setting with documentation.
Scope of delivery: Turbidity meter with calibration set 0.02-10.0-100 NTU
Specifications
Type Turb® 430 IR with infra red LED
Measuring range: NTU 0 to 1100, FNU 0 to 1100
Resolution: 0.01 in the range 0.00 to 9.99, 0.1 in the range 10 to 99.90, 1 in the range 100 to 1100
Accuracy: ± 0.01 NTU or ± 2 % of measured value
Reproducibility: 0.01 NTU or < 0.5% vof measured value
Cell size: 28 x 60 mm, 20 ml sample volume
Power supply: 4 x AA batteries for approx. 3000 measurements
Specifications
- Producent
- WTW
- Qty per Salesunit
- 1 each
- Sales Unit of Measure
- EA
- UNSPSC
- 47101516 Turbidimetre