Top of the page

Termoreactor, Lovibond RD 125, for 24 cuvettes

Item No. 9920204
Chemical digestion of samples is required for the photometric determination of COD, TOC, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor AL125. The unit works at three different temperatures (100 / 120 / 150

Description

Chemical digestion of samples is required for the photometric determination of COD, TOC, total phosphate and total nitrogen.

The required temperatures and reaction time can be selected by using the membrane keypad of the reactor AL125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times 30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm.

The AL125 reactor is fitted with 24 holes for 16 mm diameter vials.

For the digestion of:

  • COD (150°C)
  • Total Chromium (100°C)
  • Total Phosphate (100°C)
  • Total Nitrogen (100°C)
  • TOC (120°C)
Pack: 1 each

Specifications

Producent
Lovibond
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115311 Fotometer
Any questions, please contact
Customer support, b-h@buch-holm.dk, +45 44540000

Termoreactor, Lovibond RD 125, for 24 cuvettes

Item No. 9920204
Chemical digestion of samples is required for the photometric determination of COD, TOC, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor AL125. The unit works at three different temperatures (100 / 120 / 150

Description

Chemical digestion of samples is required for the photometric determination of COD, TOC, total phosphate and total nitrogen.

The required temperatures and reaction time can be selected by using the membrane keypad of the reactor AL125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times 30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm.

The AL125 reactor is fitted with 24 holes for 16 mm diameter vials.

For the digestion of:

  • COD (150°C)
  • Total Chromium (100°C)
  • Total Phosphate (100°C)
  • Total Nitrogen (100°C)
  • TOC (120°C)
Pack: 1 each

Specifications

Producent
Lovibond
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115311 Fotometer
Any questions, please contact
Customer support, b-h@buch-holm.dk, +45 44540000