Top of the page

Ubbelohde viscometer, SI Analytics, I, 1,2-10 cSt, K=0,01, uncalibrated

Item No. 9268310
Viscometers, glass, kinematic, Ubbelohde Instruments necessary for controlled accuracy, manufactured using the KPG process. Accuracy of internal capillary dia.: < &plusminus;0.01 mm. Capillary viscometers of similar types and similar capillary numbers have the same K constant. For accurate calculati

Description

Viscometers, glass, kinematic, Ubbelohde

Instruments necessary for controlled accuracy, manufactured using the KPG process. Accuracy of internal capillary dia.: < &plusminus;0.01 mm. Capillary viscometers of similar types and similar capillary numbers have the same K constant. For accurate calculation of speed gradients. The viscosity v (mm²/sec or cSt) is calculated by multiplying the constant K by the running time t: v = K x t.
Ubbelohde. To ISO/DIS 3105. DIN 51562. BS 188. NF T 60 to 100.
Without documentation of the constants.
For manual and automatic relative measurements.
Type 53010
Capillary I
Constant 0.01 K

Pack: 1 each

Specifications

Producent
SI Analytics
Type
Portable
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41103312 Viskosimetre
Any questions, please contact
Customer support, b-h@buch-holm.dk, +45 44540000

Ubbelohde viscometer, SI Analytics, I, 1,2-10 cSt, K=0,01, uncalibrated

Item No. 9268310
Viscometers, glass, kinematic, Ubbelohde Instruments necessary for controlled accuracy, manufactured using the KPG process. Accuracy of internal capillary dia.: < &plusminus;0.01 mm. Capillary viscometers of similar types and similar capillary numbers have the same K constant. For accurate calculati

Description

Viscometers, glass, kinematic, Ubbelohde

Instruments necessary for controlled accuracy, manufactured using the KPG process. Accuracy of internal capillary dia.: < &plusminus;0.01 mm. Capillary viscometers of similar types and similar capillary numbers have the same K constant. For accurate calculation of speed gradients. The viscosity v (mm²/sec or cSt) is calculated by multiplying the constant K by the running time t: v = K x t.
Ubbelohde. To ISO/DIS 3105. DIN 51562. BS 188. NF T 60 to 100.
Without documentation of the constants.
For manual and automatic relative measurements.
Type 53010
Capillary I
Constant 0.01 K

Pack: 1 each

Specifications

Producent
SI Analytics
Type
Portable
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41103312 Viskosimetre
Any questions, please contact