Top of the page

IKA Adapter Set ELVAS-1

Item No. 7971860
The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and a

Description

The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and allows measurements from 1 mPas (water temperature at 20 °C). The spindle without the water jacket can also be used in customer-specific vessels. The maximum measurable viscosity is 2000 mPas.

Specifications
Sample volume 16 ml
Viscosity Accuracy (FSR) 2 %
Viscosity Repeatibility (FSR) 0.2 %
Min. FSR match ROTAVISC lo-vi 1 mPa.s
Max. FSR match ROTAVISC lo-vi 2000 mPa.s
Min. FSR match ROTAVISC me-vi 3.2 mPa.s
Max. FSR match ROTAVISC me-vi 2000 mPa.s
Min. FSR match ROTAVISC hi-vi I 6.4 mPa.s
Max. FSR match ROTAVISC hi-vi I 2000 mPa.s
Min. FSR match ROTAVISC hi-vi II 25.6 mPa.s
Max. FSR match ROTAVISC hi-vi II 2000 mPa.s

 

Pack: 1 each

Specifications

Any questions, please contact
Carsten Andersen, can@buch-holm.dk, +45 44540055
Producent
IKA
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41103312 Viskosimetre

IKA Adapter Set ELVAS-1

Item No. 7971860
The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and a

Description

The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and allows measurements from 1 mPas (water temperature at 20 °C). The spindle without the water jacket can also be used in customer-specific vessels. The maximum measurable viscosity is 2000 mPas.

Specifications
Sample volume 16 ml
Viscosity Accuracy (FSR) 2 %
Viscosity Repeatibility (FSR) 0.2 %
Min. FSR match ROTAVISC lo-vi 1 mPa.s
Max. FSR match ROTAVISC lo-vi 2000 mPa.s
Min. FSR match ROTAVISC me-vi 3.2 mPa.s
Max. FSR match ROTAVISC me-vi 2000 mPa.s
Min. FSR match ROTAVISC hi-vi I 6.4 mPa.s
Max. FSR match ROTAVISC hi-vi I 2000 mPa.s
Min. FSR match ROTAVISC hi-vi II 25.6 mPa.s
Max. FSR match ROTAVISC hi-vi II 2000 mPa.s

 

Pack: 1 each

Specifications

Any questions, please contact
Carsten Andersen, can@buch-holm.dk, +45 44540055
Producent
IKA
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41103312 Viskosimetre