Top of the page

Naber furnace LT/B510, liftdoor, 1200°C, 15 liter

Item No. 5060210
Electrically heated muffle furnaces are ideal for daily laboratory use. Units feature rust-free, textured stainless steel exteriors. The furnances have Tmax 1100 or 1200 °C. Models feature an adjustable air inlet which is integrated in the door, an exhaust air outlet in the rear wall of the furnace

Description

Electrically heated muffle furnaces are ideal for daily laboratory use. Units feature rust-free, textured stainless steel exteriors. The furnances have Tmax 1100 or 1200 °C. Models feature an adjustable air inlet which is integrated in the door, an exhaust air outlet in the rear wall of the furnace and a silent solid state power control relay.

  • Heating on two sides by means of ceramic heating plates (heating on three sides for models L 24/11 - LT 40/12)
  • Ceramic heating plates with integral heating element which is protected from fumes and splashing, and easy to replace
  • Module lining is highly durable cured vacuum fibre
  • Double walled casing for low external temperatures and high stability
  • Fold down door (L models) can be used as work platform or lift door (LT models) with hot surface facing away from the operator
  • Non-classified insulation avoids the potential risk of cancer

The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.

Standard Equipment

•Tmax 1100 °C or 1200 °C
•Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
•Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
•Thermocouple type N (1100 °C) or type S (1200 °C)
•Ceramic heating plates with integral heating element which is safeguarded and easy to replace
•Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
•Dual shell housing made of textured stainless steel sheets 
•Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
•Adjustable air inlet integrated in door (see illustration)
•Exhaust air outlet in rear wall of furnace
•Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
•Solid state relays provide for lownoise operation
•Defined application within the constraints of the operating instructions
•NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Pack: 1 each

Specifications

Producent
Nabertherm
Max. Temperature
1100
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41102403 Laboratorieforbrændingsovne
Any questions, please contact
Janni B. Nielsen, jbn@buch-holm.dk, +45 44540017

Naber furnace LT/B510, liftdoor, 1200°C, 15 liter

Item No. 5060210
Electrically heated muffle furnaces are ideal for daily laboratory use. Units feature rust-free, textured stainless steel exteriors. The furnances have Tmax 1100 or 1200 °C. Models feature an adjustable air inlet which is integrated in the door, an exhaust air outlet in the rear wall of the furnace

Description

Electrically heated muffle furnaces are ideal for daily laboratory use. Units feature rust-free, textured stainless steel exteriors. The furnances have Tmax 1100 or 1200 °C. Models feature an adjustable air inlet which is integrated in the door, an exhaust air outlet in the rear wall of the furnace and a silent solid state power control relay.

  • Heating on two sides by means of ceramic heating plates (heating on three sides for models L 24/11 - LT 40/12)
  • Ceramic heating plates with integral heating element which is protected from fumes and splashing, and easy to replace
  • Module lining is highly durable cured vacuum fibre
  • Double walled casing for low external temperatures and high stability
  • Fold down door (L models) can be used as work platform or lift door (LT models) with hot surface facing away from the operator
  • Non-classified insulation avoids the potential risk of cancer

The muffle furnaces L 1/12 - LT 40/12 have been proven for daily laboratory use. These models stand out for their excellent workmanship, advanced and attractive design, and high level of reliability. The muffle furnaces come equipped with either a flap door or lift door at no extra charge.

Standard Equipment

•Tmax 1100 °C or 1200 °C
•Heating from two sides by ceramic heating plates (heating from three sides for muffle furnaces L 24/11 - LT 40/12) for an optimal temperature uniformity
•Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C
•Thermocouple type N (1100 °C) or type S (1200 °C)
•Ceramic heating plates with integral heating element which is safeguarded and easy to replace
•Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator
•Dual shell housing made of textured stainless steel sheets 
•Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP)
•Adjustable air inlet integrated in door (see illustration)
•Exhaust air outlet in rear wall of furnace
•Controller B510 resp. R7 for L 1/12 (5 programs with each 4 segments)
•Solid state relays provide for lownoise operation
•Defined application within the constraints of the operating instructions
•NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Pack: 1 each

Specifications

Producent
Nabertherm
Max. Temperature
1100
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41102403 Laboratorieforbrændingsovne
Any questions, please contact
Janni B. Nielsen, jbn@buch-holm.dk, +45 44540017