Top of the page

DO/BOD meter, Mettler-Toledo SevenExcellence S900-BOD, w. sensor and BOD-adapter

Item No. 6284511
Dissolved oxygen meter SevenExcellence S900 / S600 The model S900 offers a bench-top solution with OptiOxä technology: the optical measurement of dissolved oxygen. Thanks to OptiOxä, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measureme

Description

Dissolved oxygen meter SevenExcellence S900 / S600
The model S900 offers a bench-top solution with OptiOxä technology: the optical measurement of dissolved oxygen. Thanks to OptiOxä, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measurement is preferred the S600-Kit is recommended. Optical oxygen measurement is superior to conventional technologies. OptiOxä is fast, precise and produces highly reproducible results. Because of the optical measuring principle used, the oxygen is not chemically consumed during the measurement, which makes stirring the sample superfluous. The InLab OptiOxä requires no polarization time, meaning you can start your measurement immediately. In addition, the whole measuring system has a high level of stability making calibration rarely necessary.

Supplied with:
S900-BOD: As S900-Kit, also including BOD adapter.

Other types:
S900-Kit: As S900-Basic but with InLab® OptiOxä, guide to DO measurement and zero oxygen tablets.
S900-Basic: Includes instrument, DO/BOD expansion unit, 2 blank expansion units, uPlaceä electrode holder, semitransparent cover, operating instructions, installation and quick guide, LabX® direct pH PC software, declaration of conformity and test certificate.

Specifications
Measuring range (O2 Saturation)
InLab® OptiOx: 0.0 to 500 %
Resolution: 0.1 
Measuring range (O2 concentration)
InLab® OptiOx: 0.000 to 50 mg/l (ppm)
Resolution: 0.001/0.01/0.1
Accuracy
InLab® OptiOx: ±0.1 mg/l from 0 to 8
±0.2 mg/l from 8 to 20
±10 % from 20 to 50
Measuring range (Pressure): 500 to 1100 mbar
Resolution: 1
Accuracy: ±2
Calibration points: 2
Sensor input
InLab® OptiOx: MiniLTW (IP67)
Pressure compensation: automatic / manual

Type S900-BOD

Pack: 1 each

Specifications

Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022
Producent
Mettler-Toledo
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115611 Udstyr til måling af opløst ilt

DO/BOD meter, Mettler-Toledo SevenExcellence S900-BOD, w. sensor and BOD-adapter

Item No. 6284511
Dissolved oxygen meter SevenExcellence S900 / S600 The model S900 offers a bench-top solution with OptiOxä technology: the optical measurement of dissolved oxygen. Thanks to OptiOxä, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measureme

Description

Dissolved oxygen meter SevenExcellence S900 / S600
The model S900 offers a bench-top solution with OptiOxä technology: the optical measurement of dissolved oxygen. Thanks to OptiOxä, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measurement is preferred the S600-Kit is recommended. Optical oxygen measurement is superior to conventional technologies. OptiOxä is fast, precise and produces highly reproducible results. Because of the optical measuring principle used, the oxygen is not chemically consumed during the measurement, which makes stirring the sample superfluous. The InLab OptiOxä requires no polarization time, meaning you can start your measurement immediately. In addition, the whole measuring system has a high level of stability making calibration rarely necessary.

Supplied with:
S900-BOD: As S900-Kit, also including BOD adapter.

Other types:
S900-Kit: As S900-Basic but with InLab® OptiOxä, guide to DO measurement and zero oxygen tablets.
S900-Basic: Includes instrument, DO/BOD expansion unit, 2 blank expansion units, uPlaceä electrode holder, semitransparent cover, operating instructions, installation and quick guide, LabX® direct pH PC software, declaration of conformity and test certificate.

Specifications
Measuring range (O2 Saturation)
InLab® OptiOx: 0.0 to 500 %
Resolution: 0.1 
Measuring range (O2 concentration)
InLab® OptiOx: 0.000 to 50 mg/l (ppm)
Resolution: 0.001/0.01/0.1
Accuracy
InLab® OptiOx: ±0.1 mg/l from 0 to 8
±0.2 mg/l from 8 to 20
±10 % from 20 to 50
Measuring range (Pressure): 500 to 1100 mbar
Resolution: 1
Accuracy: ±2
Calibration points: 2
Sensor input
InLab® OptiOx: MiniLTW (IP67)
Pressure compensation: automatic / manual

Type S900-BOD

Pack: 1 each

Specifications

Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022
Producent
Mettler-Toledo
Qty per Salesunit
1 each
Sales Unit of Measure
EA
UNSPSC
41115611 Udstyr til måling af opløst ilt