Redox standard, Mettler-Toledo, 220 mV, pH 7, 250 mL, 6 pcs

Item No. 6801283
Redox (ORP) Buffer solution from Mettler-Toledo This 220 mV ORP standard (pH = 7) acts as a control or reference material, rather than as a calibration standard. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. with a

Description

Redox (ORP) Buffer solution from Mettler-Toledo

This 220 mV ORP standard (pH = 7) acts as a control or reference material, rather than as a calibration standard. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. with a pH value of 7, it can double as a pH buffer.

The standard controls the functionality of the sensing and reference electrode, the analysts technique, environmental conditions, and the operation of the measuring meter. This standard has a long shelf life. The value of 220 mV refers to the potentials of the metal electrode versus the reference electrode (often Ag/AgCl with 3 mol/L KCl reference electrolyte).

Specifications

  • Potential: 220 mV (25 °C)
  • pH value: 7
  • Volume: 6 x 250 mL
Pack: 6 each/pack

Specifications

Producent
Mettler-Toledo
Volume [ml]
250
Qty per Salesunit
6 each/pack
Sales Unit of Measure
PK
UNSPSC
41116107 Kvalitetskontroller, kalibratorer eller standarder til kemi
Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022

Redox standard, Mettler-Toledo, 220 mV, pH 7, 250 mL, 6 pcs

Item No. 6801283
Redox (ORP) Buffer solution from Mettler-Toledo This 220 mV ORP standard (pH = 7) acts as a control or reference material, rather than as a calibration standard. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. with a

Description

Redox (ORP) Buffer solution from Mettler-Toledo

This 220 mV ORP standard (pH = 7) acts as a control or reference material, rather than as a calibration standard. This is because Redox Oxidation/Reduction (ORP) is an absolute measurement and the sensing electrode does not require calibration. with a pH value of 7, it can double as a pH buffer.

The standard controls the functionality of the sensing and reference electrode, the analysts technique, environmental conditions, and the operation of the measuring meter. This standard has a long shelf life. The value of 220 mV refers to the potentials of the metal electrode versus the reference electrode (often Ag/AgCl with 3 mol/L KCl reference electrolyte).

Specifications

  • Potential: 220 mV (25 °C)
  • pH value: 7
  • Volume: 6 x 250 mL
Pack: 6 each/pack

Specifications

Producent
Mettler-Toledo
Volume [ml]
250
Qty per Salesunit
6 each/pack
Sales Unit of Measure
PK
UNSPSC
41116107 Kvalitetskontroller, kalibratorer eller standarder til kemi
Any questions, please contact
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022